Last month, I talked about how you can make sure your system has the ability to report problems back to IBM in the event of a failure. That functionality can be invaluable for keeping your system running, but what happens if something goes wrong while the OS is still trying to start? What if something fails so far down the hardware stack that the system simply can’t be aware of it before the whole show grinds to a halt? That’s where an HMC has your back, and it can call

Posted on May 28, 2019

We recently had a customer with a power outage and the HMC and AS400 went down hard.  When the power was restored the AS400 was ready to come up, but the HMC had a hard drive crash. If your HMC is set up right you can just push the button on the AS400 and it should start up.  But this time it wouldn’t power on, the reason was the HMC “Power-On Parameter” policy was set to, User-Initiated.  This needs to be set to Auto Start – Always for this option